Norcold 2118IM Service Manual page 27

Gas electric refrigerators
Hide thumbs Also See for 2118IM:
Table of Contents

Advertisement

Available languages

Available languages

Diagnostic Mode, cont'd.
1
Food compartment light is off and door is closed.
2
Flame is sensed.
3
Thermistor is sensing fin temperature.
4
Not used.
5
Not used.
6
Not used.
7
Not used.
Screen 8. Power Board Outputs
Press the MODE button to bring up screen 8.
Diagnostic Screen 9 (Initial View)
Diagnostic Screen 8 (Initial View)
Screen 8 (Initial view)
Screen 8 displays "live" power board outputs using lighted LED
segments. The following illustration provides definitions of the
"live" outputs indicated by the individual LED segments. If a power
board output is active or "live," its assigned output LED seg-
ment will be on.
Diagnostic Screen 8 (Second View)
Not used
DC power to
light switch
Individual Segment Identification
1
AC heater relay is energized.
2
Not used.
3
DC power to divider heater.
4
Gas valve relay is energized.
5
DC power to light switch.
6
DC power to ignition circuit.
7
Not used.
www.norcold.com
Diagnostic Screen 8 (Second View)
Screen 8 (Second view)
All segments shown as being on
Not used
DC power to
light switch
AC heater relay is energized
1
2
3
DC power to divider heater
4
Gas valve relay is energized
6
5
DC power to ignition circuit
7
Not used
Screen 9. Power Board DC Input Voltage Status
Press the MODE button to bring up screen 9.
Diagnostic Screen 9 (Initial View)
Screen 9 (Initial view)
Screen 9 displays DC voltage status using lighted LED segments.
Refer to illustration below for definitions of the individual LED seg-
ments. If DC voltage at the power board is within normal range
(10.5 to 15.4 VDC), LED segment 4 will be on.
Diagnostic Screen 9 (Second View)
Not used
AC heater relay is energized
1
Not used
2
3
DC power to divider heater
4
Gas valve relay is energized
6
5
DC power to ignition circuit
7
Not used
Individual Segment Identification
1
DC voltage higher than 15.4 volts.
2
Not used.
3
Not used.
4
DC voltage normal.
5
Not used.
6
Not used.
7
DC voltage lower than 10.5 volts.
Screen 0. Power Board AC Input Voltage Status
Press the MODE button to bring up screen 0.
Diagnostic Screen 9 (Initial View)
Screen 0 (Initial view)
Screen 0 displays AC voltage status using lighted LED segments.
Refer to illustration below for definitions of the individual LED seg-
ments.
27
Diagnostic Screen 9 (Second View)
Screen 9 (Second view)
All segments shown as being on
DC voltage higher than 15.4 volts
1
2
3
Not used
4
DC voltage normal
6
5
Not used
7
DC voltage lower than 10.5 volts
Diagnostic Screen 9 (Second View)
Screen 0 (Second view)
All segments shown as being on
DC voltage higher than
1
Not used
2
3
Not used
4
DC voltage normal
Not used
5
6
Not used
7
DC voltage lower than 1
AC voltage higher tha
1
Not used
2
3
Not used
4
AC voltage normal
Not used
5
6
Not used
7
AC voltage lower than