No Ac, No Fl; Ac Re; Ac He; Op Li - Norcold 2118IM Service Manual

Gas electric refrigerators
Hide thumbs Also See for 2118IM:
Table of Contents

Advertisement

Available languages

Available languages

Fault Codes, cont'd.

no AC, no FL

code
code
Meaning:
This fault is a combination of two separate faults. First, the Power
Board sensed the AC input voltage to be less than 85VAC and
automatically switched to the LP Gas Mode. Secondly, the Power
Board was then unable to detect a flame while operating in the
Auto Gas Mode. This fault can only be displayed while operating in
the Auto Mode.
Verify:
■ Follow the "Verify" instructions for the "no AC" fault and "no FL".
■ If all the steps listed under Verify the "no AC" and the "no FL"
codes check good, replace power board.

AC rE

code
Meaning:
The AC heater relay contacts of relay K2, on the Power Board, are
stuck closed. This fault can be displayed in ANY MODE.
■ Replace the Power Board.
2118, 2118IM, 2118IMD Series

AC HE

code
code
Meaning:
The Power Board sensed the AC heater current to be too low. This
fault can only be displayed while operating in the Manual AC Mode.
Verify:
■ AC heater connections are in good repair and are properly
code
code
connected to the Power Board. (Refer to Fig. 17 and Fig. 18
refrigerator wiring diagrams for proper connection.)
NOR000124A-noac_no
■ AC heater resistance measures between 45Ω and 51Ω:
■ No - replace AC heater.
■ Contact Customer Service for further instructions.

oP LI

Meaning:
Refer to the flow chart(s) that are on the next four (4) pages.
code
code
NOR000124A-acre
18
036
code
code
code
code
NOR000124A-ache
code
code
NOR000124A-opli
www.norcold.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents