Troubleshooting - STEINEL GL 60 S Series Installation Instructions Manual

Table of Contents

Advertisement

Technical specifications
Wattage:
100 watts max./E 27 or 2 x 40 W max./G9 for glass globes
100 watts max./E 27 or 3 x 40 W max./G9 for glass cylinders
Voltage:
230 – 240 V, 50 Hz
Angle of coverage:
360° with 30° angle of aperture
Sensor reach:
12 m max.
Time setting:
5 sec. – 15 min.
Twilight setting:
2 – 2000 lux
Brightness control:
0 – 50% (Watt-o-matic)
Manual override:
selectable (4 hours) provided
switch is connected in mains supply lead
Enclosure:
IP 44
Functions
,
,
The SensorLight can be put into service after mount-
ing the sensor unit and connecting the light to the
mains power supply. The controls for adjusting
Twilight setting
(response threshold)
(factory setting:
daylight operation 2000 lux)
2 - 2000 Lux
Switch-off delay
(time setting)
(factory setting: 5 sec.)
5 sec.-15 min
Brightness control
(Watt-o-matic)
(factory setting:
dimmer off: 0%)
0 - 50%
Reach setting / adjustment
The sensor has a maximum reach of 12 m. The
detection zone can be optimised to suit individual
needs. The shrouds provided are used for blanking
out any number of lens segments or to shorten reach
as required. This prevents the light from being activat-
ed unintentionally, e.g. by cars, passers-by etc. and
response threshold, time and brightness are pos-
itioned next to the bulb holder.
Sensor response threshold can be infinitely varied
from 2 – 2000 lux.
Control dial set to
= daylight operation
approx. 2000 lux.
Control dial set to
= twilight operation
approx. 2 lux. To adjust the detection zone in daylight,
set control dial to
(daylight operation).
Light ON duration can be infinitely varied from
5 sec. to 15 min.
Control dial set to – = shortest time
Control dial set to + = longest time (15 min.)
It is recommended to select the shortest time
– when adjusting the detection zone
Light output can be infinitely adjusted up to 50 % of
maximum power when set to stay on all the time.
This means: when the light is set to stay on all the
time, it will only switch from, say, 20 watts to max-
imum light output (120 watts/G9 or 100 watts/E27)
when movement occurs in the sensor detection zone.
allows to you to target danger spots. The shrouds
can be divided or cut with a pair of scissors along the
vertical and horizontal grooves. Turning the sensor
unit permits final precision adjustment.
- 10 -
Manual override function
If a mains switch is installed in the mains supply lead,
the light is capable of the following functions in add-
ition to the simple ON/OFF function:
Sensor operation
1) Switch light ON (when light is OFF):
Switch OFF and ON once.
Light stays ON for the period selected.
2) Switch light OFF (when light is ON):
Switch OFF and ON once.
Light goes out or switches to sensor mode.
Soft light start
The sensor light features a soft light start function.
This means that when turned ON, the light is not
switched directly to maximum output but gradually

Troubleshooting

Malfunction
Cause
SensorLight without power
Fuse faulty, not switched
on, break in wiring
Short circuit
SensorLight will not switch ON
Twilight control set to night-time
mode during daytime operation
Bulb faulty
Mains switch OFF
Fuse faulty
Detection zone not properly
targeted
Internal electrical fuse
has been activated
(LED ON all the rime)
SensorLight will not switch OFF
Continuous movement in the
detection zone
Set brightness control to 50%
SensorLight switches on when it
Wind is moving trees and
should not
bushes in the detection zone
Cars in the street are being
detected
Sudden temperature changes
due to weather (wind, rain,
snow) or air expelled from
fans, open windows
SensorLight reach has changed
Change in ambient
temperatures
LED ON all the time although
Internal fuse activated
manual override is not selected
Manual override
1) Select manual override:
Switch OFF and ON twice. The light will stay ON for
4 hours (red LED lights up behind the lens). Then it
returns automatically to sensor mode (red LED OFF).
2) Deactivate manual override:
Switch OFF and ON once. Light goes out or switches
to sensor mode.
Important:
The switch should be actuated in rapid succession
(in the 0.5 – 1 sec. range).
builds up brightness to 100% within the space of a
second. Brightness is also gradually reduced when
the light is switched OFF.
Remedy
Fit new fuse, turn mains switch
on; check wiring with
voltage tester
Check connections
Re-adjust (control
)
Change bulb
Switch on
Fit new fuse, check connection
if necessary
Re-adjust
Switch sensor light OFF and
back ON again after about
5 sec.
Check detection zone and
re-adjust if necessary
Set brightness control to 0%
(control
)
Change detection zone
Change detection zone
Change detection zone,
change site of installation
Use shrouds to adjust detection
zone accurately
Switch sensor light OFF and
back ON again after 5 sec.
- 11 -

Advertisement

Table of Contents
loading

Table of Contents