2. Wiring Diagram

NFB
3-phase 200VAC
Regenerative
brake option
When connecting the external regenerative
brake option, always disconnect
the jumper from across P-D.
Zeroing completion
Proximity dog
Servo on
Forward rotation stroke end
Reverse rotation stroke end
Automatic/manual selection
Point table No. selection 1
Point table No. selection 2
Forward rotation start
Reverse rotation start
Rough match
In position
Trouble
Ready
Upper limit setting
Upper limit setting
External torque limit
Servo amplifier
MR-J2S-A-S061
MC
L1
L 2
L 3
L11
L12
C
D
P
10m(39.37inch) max.
CN1 A
9
COM
18
ZP
RA 1
8
DOG
10
SG
SG
20
10m (39.37inch) max.
CN1B
SON
15
16
LSP
LSN
17
MD0
7
DI0
5
DI1
14
ST1
8
9
ST2
SG
10
SG
20
3
VDD
13
COM
CPO
4
RA2
6
INP
RA3
ALM
18
RA4
19
RD
RA5
11
P15R
VC
2
LG
1
12
TLA
SD
Plate
2m(78.74inch) max.
TE1
U
V
W
TE2
Emergency stop
To be shut off when servo on signal
switches off or alarm occurs.
CN 2
Encoder cable
(Available as option or to be fabricated)
Communication cable
CN3
(Available as option or to be fabricated)
CN3
4 MO1
3
LG
14 MO2
LG
13
SD
Plate
5
Servo motor
U (Red)
V (White)
SM
W (Black)
(Green)
Electromagnetic
B1
brake
B2
Encoder
A
Monitor output 1
10 k
A
Monitor output 2
10 k
BCN-B11127-479*