Technical Data
Light Measuring Range : Using ASA 1 0 0 film
:
EV 1.5 1/2sec.-EV -4.5
30sec. at F 1.2.
Measuring Method : Zero-method direct reading
type.
Photocell:
Utilizes CdS cell of the camera.
Exposure Time Dial:
In
the case of PELLlX QL;
60,30,15,8,4,2,1,112,1/4,1/8,1/15,1/30sec.
Power Sources:
For operating meter, use two
1.3V M 2 0 (#625) mercury batteries.
For
illumination of
meter indicator window,
use one 1.3V M20 mercury battery (use the
battery removed from the camera].
Battery Check: Can be checked by the switch.
Size : 6 5 x 5 4 x 39mm ( 2 % " ~ 2 % " ~ 1%").
Weight: 1 8 0 grams i6?4 oz.!.