Problem solving guide
Problem
The compressor is
switching on more fre-
quently and for longer
periods of time, the
temperature in the wine
conditioning unit is fall-
ing.
The compressor comes
on less and less often
and for shorter periods
of time. The temperat-
ure in the wine condi-
tioning unit rises.
36
Cause and remedy
The temperature in the wine conditioning unit is set
too low.
Adjust the temperature.
The appliance door is not properly closed.
Check that the appliance door closes properly.
The appliance door has been opened too frequently.
Only open the door when necessary and for as
short a time as possible.
The ventilation gaps have been covered over or be-
come dusty.
Do not cover the ventilation gaps and dust them
regularly.
The air filter is dusty.
Clean the air filter (see "Cleaning and care").
The ambient room temperature is too warm.
Decrease the ambient room temperature.
This is not a fault. The temperature is too high.
Adjust the temperature.
Check the temperature again after 24 hours.
The air filter in the plinth is soiled.
Clean the air filter in the appliance plinth (see
"Cleaning and care").