Carrier 50HCQA05 Service And Maintenance Instructions page 49

Single package heat pump/electric heat nominal 3 to 10 tons with puron r-410a refrigerant
Hide thumbs Also See for 50HCQA05:
Table of Contents

Advertisement

Table 18 – 50HCQA05
4 TON HORIZONTAL UNIT DIRECT DRIVE
SPEED
(TORQUE)
CFM
TAP
1200
1300
1400
1500
1
1600
1700
1800
1900
2000
1200
1300
1400
1500
2
1600
1700
1800
1900
2000
1200
1300
1400
1500
3
1600
1700
1800
1900
2000
1200
1300
1400
1500
4
1600
1700
1800
1900
2000
1200
1300
1400
1500
5
1600
1700
1800
1900
2000
APPENDIX III. FAN PERFORMANCE (cont.)
ESP
BHP
0.93
0.48
0.80
0.46
0.66
0.44
0.51
0.41
0.36
0.39
0.22
0.36
0.08
0.33
---
---
---
---
1.04
0.53
0.91
0.51
0.76
0.48
0.61
0.46
0.45
0.43
0.30
0.40
0.16
0.38
0.04
0.35
---
---
1.18
0.58
1.09
0.59
0.98
0.60
0.86
0.60
0.72
0.57
0.57
0.54
0.42
0.51
0.28
0.48
0.15
0.45
1.24
0.60
1.18
0.63
1.12
0.66
1.04
0.71
0.95
0.70
0.85
0.71
0.73
0.71
0.60
0.69
0.45
0.65
1.25
0.61
1.20
0.65
1.12
0.68
1.04
0.68
1.05
0.76
1.01
0.76
0.96
0.84
0.91
0.89
0.87
0.93
Table 19 – 50HCQA05
4 TON VERTICAL UNIT DIRECT DRIVE
SPEED
(TORQUE)
CFM
TAP
1200
1300
1400
1500
1
1600
1700
1800
1900
2000
1200
1300
1400
1500
2
1600
1700
1800
1900
2000
1200
1300
1400
1500
3
1600
1700
1800
1900
2000
1200
1300
1400
1500
4
1600
1700
1800
1900
2000
1200
1300
1400
1500
5
1600
1700
1800
1900
2000
49
ESP
BHP
0.87
0.43
0.73
0.41
0.59
0.39
0.43
0.37
0.27
0.34
0.12
0.33
---
---
---
---
---
---
0.96
0.48
0.84
0.46
0.69
0.44
0.53
0.41
0.37
0.39
0.21
0.36
0.06
0.34
---
---
---
---
1.13
0.53
1.06
0.53
0.98
0.54
0.88
0.56
0.76
0.54
0.62
0.52
0.47
0.50
0.31
0.47
0.15
0.45
1.16
0.57
1.12
0.59
1.07
0.62
1.00
0.67
0.91
0.66
0.80
0.67
0.67
0.67
0.52
0.63
0.35
0.61
1.16
0.59
1.11
0.63
1.01
0.67
0.91
0.67
0.96
0.75
0.91
0.75
0.86
0.83
0.80
0.87
0.74
0.91

Advertisement

Table of Contents
loading

This manual is also suitable for:

50hcqa0450hcqd0850hcqa0650hcqd0950hcqd1250hcqa07

Table of Contents