■ Checking the limit switches of the outriggers
(before any use)
To check the limit switches L of the outriggers:
Lower the outriggers to the ground and attempt to
engage a gear.
If the gear can be engaged, contact the GENIE
Technical Service.
With the outriggers up, light 8 on the moment
limiter panel must be off; with the outriggers down
to the ground, the same light must be on. Should
that not be the case, contact the GENIE Technical
Service.
■ Micro-switch H on the parking brake
(before any use)
To check the efficiency of the parking brake micro-
switch, simply sit in the driving place, start the
engine and attempt to move the machine with the
parking brake engaged. The machine should not
move. Should that not be the case, adjust or
replace the proximity sensor on the parking brake.
■ Checking the proximity switches
Sensor I on the boom
Raise the boom beyond the horizontal and ensure
the sway control and the outrigger control are
blocked.
Should that not be the case, contact the GENIE
Technical Assistance Service.
For the adjustment of the proximity switches, read
chap. D-3.14.
If the trouble does not depend on the sensor adjustment,
contact the GENIE Technical Assistance Service.
Handler with telescopic boom GTH-3512