SUMMARY
INTRODUCTION ........................................................... 1
DESCRIPTION .............................................................. 2
CHARACTERISTICS ..................................................... 2
LABELLING ................................................................... 3
DIMENSIONS AND WEIGHTS ...................................... 4
OPERATION .................................................................. 4
INSTALLATION ............................................................. 5
COMMISSIONING ......................................................... 6
MAINTENANCE ............................................................ 7
SPARE PARTS .............................................................. 10

INTRODUCTION

The type REGAL 3F is a direct-operated, spring set point
pressure regulator, used for supplying industries and
commercial businesses.
As an option, it can be equipped with a slam shut types VSX2
or OS2 which permits the gas fl ow to be cut off rapidly and
totally in the case of under or over outlet regulator pressure.
DECLARATION OF CONFORMITY REGAL 3F
Manufacturer:
Address:
Equipment:
Conformity Assessment Module:
The undersigned declare that the design, manufacture and inspection of this equipment are in conformity with the Pressure Equipment
Directive 2014/68/UE (PED)
Name:
Date:
FRANCEL
3 avenue Victor Hugo, 28008 Chartres
REGAL 3F
Module A
Function:
Signature:
Type Regal 3F/VSX2
Figure 1. Type REGAL 3F Direct-Operated Regulator
The type REGAL 3F is in conformity with the Pressure
Equipment Directive PED 2014/68/UE and is classifi ed
under category I.
Equipment and pipeline situated on the outlet side of
the regulator are either;
• not subject to the PED (Pu <= 0.5 bar), or
• subject to (Pu > 0.5 bar): in this case the type
Regal 3F is classifi ed under category 1 maximum.
Identifi cation no.:
Company stamp:
REGAL 3F
Type Regal 3F/OS2

Advertisement

Table of Contents
loading

Summary of Contents for Emerson REGAL 3F

  • Page 1: Table Of Contents

    SPARE PARTS .............. 10 Figure 1. Type REGAL 3F Direct-Operated Regulator INTRODUCTION The type REGAL 3F is in conformity with the Pressure Equipment Directive PED 2014/68/UE and is classifi ed The type REGAL 3F is a direct-operated, spring set point under category I.
  • Page 2: Description

    (the actuator can be removed without disconnecting the impulse pipeline). A tripping spring set to min CHARACTERISTICS Table 1. General Characteristics for Type Regal 3F Regulator Operating pression REGULATOR AC 5 Body, valve plug, slam shut...
  • Page 3: Labelling

    Min (mbar) Max (mbar) Fisher Ressort/Spring Ø Plage / Range 100 / 350 260 / 600 Tarage / Set nominal Wdsu Wdso Type VSX2 slam shut label Type OS2 slam shut label Figure 2. Type Regal 3F/VSX2 and Type Regal3F/OS2 Labels...
  • Page 4: Dimensions And Weights

    Without slam shut : 18 kg 180* * Disassembly dimentions VSX2 Figure 3. Type Regal 3F/VSX2 and Type Regal3F/OS2 Dimensions (mm) OPERATION The type Regal 3F is a pressure regulator with expansion achieved by a balanced valve plug and pressure control by a Adjustment screw direct-operated actuator.
  • Page 5: Installation

    IS : VSX2 s lam shut impulse IS : OS2 slam shut impulse Figure 6. Type Regal 3F/VSX2 and Type Regal3F/OS2 Installation Schematic Version with integral slam shut, it is CAUTION recommended to install an isolation valve (R1) and an atmospheric valve (R2), which All interventions on equipment should are useful for tripping and verifi...
  • Page 6: Commissioning

    REGAL 3F The user should verify or carry out a • 1 release relay stage protection adapted to the environment. - Set (Stage 1) Version with slam shut, if the outlet side is • Slam shut valve plug subject to the PED and not protected by any...
  • Page 7: Maintenance

    - Observe the evolution of the outlet pressure (control Verifi cation regulator tightness) • Verifi cation of the set point Table 6. Troubleshooting for Type Regal 3F/VSX2 and Type Regal 3F/OS2 Regulators SYMPTOMS CAUSE ACTIONS Control the regulator valve plug...
  • Page 8 Tools Male spanners for six-sided wrench: 2.5, 4 and 6 Flat spanner: 10 Figure 8. Type Regal 3F/VSX2 and Type Regal 3F/OS2 detail Box spanner: 30 and 46 2 fl at spanners for fl anges: 24 Adjustment spanner for VSX2: Ref. 197 226...
  • Page 9 REGAL 3F Slam Shut Version with Type VSX2 integral slam shut • Disconnect the impulse pipe (IS) • Unscrew the screws (key 14) and remove the VSX2 slam shut • Control the valve plug (key 13) • Disassembly : see D103683X012 manual Version with Type OS2 integral slam shut •...
  • Page 10: Spare Parts

    REGAL 3F SPARE PARTS Figure 9. Type Regal 3F/VSX2 and Type Regal 3F/OS2 Spare Parts detail...
  • Page 11 REGAL 3F Table 7. Spare Parts Item Description Reference Valve plug assembly 181 058 O-ring 400 506 Diaphragm 142 033 Clutch O-ring 400 505 Spring See Table 3 Cap O-ring 400 080 Screw 403 030 Actuator/body O-ring 400 029 Truarc ring...
  • Page 12 Electric Co. All other marks are the property of their prospective owners. T +1 800 558 5853 T +65 6770 8337 Francel™ is a mark owned by Francel SAS, a business of Emerson +1 972 548 3574 Automation Solutions. Europe...