ECONO COOL OPERATION

Use this operation when you want to be comfortable in COOL mode even with energy saved.
˚C
CLOCK
AMPM
AMPM
TOO
TOO
ON/OFF
WARM
COOL
FAN
STOP
I FEEL COOL
VANE
START
HEAT
DRY
/FAN
MODE
HR.
ECONO COOL
MIN.
RESET CLOCK
What is "ECONO COOL"?
Swing air flow (change of air flow) makes you feel cooler than constant air flow. So, even though the set temperature is
automatically set 2°C higher, it is possible to perform cooling operation with keeping comfort. As a result, energy can be saved.

TIMER OPERATION (ON/OFF TIMER)

It is convenient to set the timer when you go to bed, when you get home, when you get up, etc.
How to set the ON timer
1
START
Press the
button during operation.
Each time the button is pressed, the ON timer mode
alternates between ON and OFF.
2
Set the time of the timer using the
MIN.
buttons.
HR.
Each time the
button is pressed, the set time in-
creases by 1 hour; each time the
the set time increases by 10 minutes.
To release the ON timer:
I
START
Press the
button.
Programming timer operation
The ON timer and the OFF timer can be used in combination. The timer of the set time that is reached first will operate first.
(" " mark indicates the order of timer operations.)
• If the current time has not been set, the timer operation cannot be used.
NOTE:
If the main power is turned off or a power failure occurs while AUTO START/STOP timer is active, the timer setting is
cancelled. As these models are equipped with an auto restart function, the air conditioner starts operating with timer
cancelled at the same time that power is restored.
8
Perform the following operations while the unit is operat-
ing in the MANUAL COOL mode.
I
ECONO COOL
Press the
button.
When the
(ECONO COOL) operation is selected in COOL mode, the air
conditioner performs swing operation in various cycle according to the tempera-
ture of air conditioner.
Also SET TEMPERATURE is automatically set 2°C higher than in COOL mode.
To release the ECONO COOL operation:
I
ECONO COOL
Press the
button again.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
VANE
• When the
button is pressed or the operation mode is changed during
the ECONO COOL operation, ECONO COOL operation is released.
TOO
FAN
WARM
• The
button, the
or
are available.
How to set the OFF timer
1
Press the
Each time the button is pressed, the OFF timer mode
alternates between ON and OFF.
HR.
2
and
Set the time of the timer using the
MIN.
Each time the
MIN.
button is pressed,
creases by 1 hour; each time the
the set time increases by 10 minutes.
To release the OFF timer:
I
Press the
TOO
COOL
button and ON/OFF timer (explained below)
STOP
button during operation.
buttons.
HR.
button is pressed, the set time in-
MIN.
button is pressed,
STOP
button.
WHEN THE AIR CONDI
USED FOR A LONG TIM
When it is not going to be used for a lo
time:
1
Perform the FAN operation for 3 or 4 h
to dry the inside of the air conditioner.
COOL & HEAT type:
• To perform FAN operation, set the remote c
ler to the highest temperature in the MANUAL
mode. (Refer to page 7.)
COOL ONLY type:
• Select the FAN mode. (Refer to page 7.)
2
Turn off the breaker and/or disconnec
power supply plug.
CAUTION:
Turn off the breaker or disconnect the power suppl
when the air conditioner is not going to be used
long time.
Dirt may collect and this may cause a fire.
3
Remove the batteries from the remote
troller.
CAUTION:
To prevent liquid leakage, take out all batteries wh
remote controller is not going to be used for a long

MAINTENANCE

HR.
Before starting maintenance
and
I
Turn off the breaker and/or disconnec
power supply plug.
CAUTION:
When the unit is to be cleaned, switch it off and d
nect the power supply plug or turn off the breaker.
the fan rotates at high speed during operation,
cause an injury.