INSTALLATION, RELOCATION AND INSPECTION

Installation place
Avoid installing the air conditioner in the following places.
• Where flammable gas could leak.
CAUTION:
Do not install the unit where flammable gas could leak.
If gas leaks and collects around the unit, it may cause
an explosion.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfide gas is generated such as a hot spring.
• Where oil is splashed or where the area is filled with
oily smoke.
• Where there is high-frequency or wireless equipment.
WARNING :
If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since
there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not
when repairs are carried out.
The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas
leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be
generated.
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
WARNING :
• The customer should not install this unit.
If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking,
etc.
• Do not use intermediate connection of the power supply cord or the extension cord and do not connect many
devices to one AC outlet.
A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.

SPECIFICATIONS

Set name
Model
Indoor
Outdoor
Function
Power supply
Capacity
Input
Indoor
Weight
Outdoor
Refrigerant filling
capacity (R410A)
Indoor
IP code
Outdoor
Permissible
LP ps
MPa
excessive
operating
HP ps
MPa
pressure
Indoor
dB(A)
Noise level
(High/Med./Low)
Outdoor
dB(A)
To prevent the effects
of a fluorescent lamp,
keep as far apart as
possible.
1 m
or more
MSH-A07YV
MSC-A07YV
MUH-A07YV
Cooling
Heating
Cooling
kW
2.3
2.5
kW
0.715
0.69
kg
9
kg
35
kg
0.62
36/31/25
36/31/25
47
The installation location of the outdoor unit should be
at least 3 m away from the antennas for TV sets,
radios, etc. In areas where the reception is weak, pro-
Inverter-type
vide greater space between the outdoor unit and the
fluorescent lamp
antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
Keep a space
to prevent the
picture
distortion or
100 mm or
the noise.
more
TV
1 m
or more
Cordless
phone or
Portable
Radio
phone
3 m
or more
MSH-A09YV
MSH-A12YV
MSC-A09YV
MSC-A12YV
MUH-A09YV
MUH-A12YV
Heating
Cooling
2.55
3.05
3.5
0.795
0.84
1.09
10
38
40
1.00
1.00
39/32/25
40/33/26
49
CAUTION:
• Earth the unit.
Do not connect the earth to a gas pipe, water
incorrect, it may cause an electric shock.
wall, etc.
• Install an earth leakage breaker depending on t
etc.).
Well-
If the earth leakage breaker is not installed, it m
ventilated
dry place
Inspection and maintenance
500 mm or
• When the air conditioner is used for several sea
more
• Depending on the condition, an odor may be g
dust, etc.
• It is recommended that the unit be inspected an
Consult your dealer.
Operating sound considerations
• Do not put an object around the air outlet of the
operating sound.
• If an abnormal sound is heard during operation
Relocation
• When the air conditioner is to be removed or re-i
are required.
WARNING :
Repairs or relocation should not be done by the c
If this is done incorrectly, it may cause a fire, an
Consult your dealer.
Disposal
To dispose of this product, consult your dealer.
MS-A07YV
MSC-A07YV
MU-A07YV
Heating
~ /N, 230V, 50Hz
3.9
2.3
1.08
0.715
0.60
IP20
IP24
1.64
4.15
36/31/25
39/33/26
If you have any
MS-A09YV
M
MSC-A09YV
MS
MU-A09YV
M
Cooling
2.55
0.795
9
34
0.60
45
4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Msc-a09yvMsc-a12yv