Disassembly And Parts Replacement
Basic Precautions
Always turn off the electric power supply before servicing or replacing any electrical component.
If grounding wires, screws, straps, clips, nuts, or washers used to complete a path to ground are
removed for service, they must be returned to their original position and properly fastened.
Make sure the power cord is not damaged.
IMPORTANT: EMPTY CONTENTS OF UNIT
AND DISCONNECT FROM POWER SOURCE
BEFORE ATTEMPTING ANY REPAIRS.
Drain Pump Removal and Replacement
The drain pump functions to drain wash water after each cycle has been completed.
Tools Needed:
- Phillips Screwdriver
Step 1: Remove Base Tray Cover
Turn the unit over to locate the Base Tray Cover
Tip: Take a photo of the original assembly configuration for reference when reinstalling the panel.
Remove the screw that is circled in the photo below and set aside.
- Flat Tip Screwdriver
- Needle Nose Pliers
13