Boot Menu - Siemens SIMATIC HMI IPC677C Operating Instructions Manual

Hide thumbs Also See for SIMATIC HMI IPC677C:
Table of Contents

Advertisement

16.4.9

Boot Menu

In this menu this booting behavior of the device is specified and the boot medium or
sequence of the boot media is determined.
Figure 16-15 Boot Menu
Entry
Quick Boot
Quiet Boot
POST errors
Numlock
USB Boot
PXE Boot to LAN 1
PXE Boot to LAN 2
EFI>
Legacy>
SIMATIC HMI IPC677C
Operating Instructions, 04/2013, A5E02722710-04
Meaning
Enable or disable
If enabled, the programming device starts faster because various hardware
function tests are skipped.
Booting is carried out in text mode.
Specification of the booting behavior if errors are recognized.
Never halt on errors: Continue the booting process when errors occur.
Halt on all errors: Interrupt the booting process when errors occur.
All without keyboard: Interrupt the booting process when errors occur,
except for keyboard errors.
All without kb/smart: Interrupt the booting process when errors occur,
except for keyboard and S.M.A.R.T errors. (SMART: Self-Monitoring,
Analysis and Reporting Technology)
On = Enable numeric keypad on right
Off = Disable numeric keypad on right (= navigation)
Allow/Do not allow booting of inserted USB devices.
Enable or disable booting of the LAN1.
Enable or disable booting of the LAN2.
Set order of the EFI boot media
Set traditional boot order (Normal, Advanced, Advanced Placeholder).
Detailed descriptions
16.4 BIOS-Setup
239

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents