13.2

Problems when Using Modules of Third-party Manufacturers

Problem
Possible cause
The PC crashes
Double allocation of I/O
during startup
addresses
Double allocation of hardware
interrupts and/or DMA channels
Signal frequencies or signal
levels are incorrect.
Different connector pin
assignments
If the performance of the
external 24 V power supply is
insufficient
13.3

Display a temperature error by means of the DiagBase application

Cause
Temperature errors do not occur during the normal approved use of the device. If the
monitoring software (DiagBase or DiagMonitor) indicates a temperature error and the symbol
in the status display changes from green to red, check the following:
● Are the fan apertures covered?
● Has the fan has failed (check speed display in the monitoring software)?
● Is the ambient temperature higher than the allowed value (see technical data)?
● Is the total output of the power supply within the specified limit?
● Are the heatsinks inside the PC covered with dust?
Remedy
The temperature fault is stored until the temperature drops back below the temperature
threshold and you acknowledge the error message in the monitoring software.
● Click on the button with the "small broom" icon.
● Restart the PC if you have not installed the monitoring software.
SIMATIC HMI IPC677C
Operating Instructions, 04/2013, A5E02722710-04
When the error message has been acknowledged, the "TEMP" LED goes out, the title bar
changes in the monitoring software and the symbol in the status bar changes from red to
green.
13.2 Problems when Using Modules of Third-party Manufacturers
Remedy
Check your computer configuration:
If the computer configuration corresponds with factory state,
please contact your technical support team.
If the computer configuration has changed, restore the
original factory settings. Remove all third-party modules,
then restart the PC. If the error no longer occurs, the third-
party module was the cause of the fault. Replace this
module with a Siemens module or contact the module
supplier.
Contact Technical Support if the PC still crashes.
use a larger power supply.