Alignment
Alignment Preparation & Precautions
A 50-Ohm RF Dummy Load and in-line wattmeter
must be connected to the main antenna jack in all
procedures that call for transmission, except where
specified otherwise. Correct alignment is not possi-
ble with an antenna.
After completing one step, read the following step
to determine whether the same test equipment will
be required. If not, remove the test equipment (ex-
cept dummy load and wattmeter, in connected) be-
fore proceeding.
Correct alignment requires that the ambient temper-
ature be the same as that of the transceiver and test
equipment, and that this temperature be held con-
stant between 68 and 86 °F (20 ~ 30 °C). When the
transceiver is brought into the shop from hot or cold
air, it should be allowed time to come to room tem-
perature before alignment.
Whenever possible, alignments should be made with
oscillator shields and circuit boards firmly affixed in
place. Also, the test equipment must be thoroughly
warmed up before beginning.
Note: Signal levels in dB referred to in the alignment
procedure are based on 0 dBm EMF = 1 mV.
Deviation
Meter
30 dB PAD
Frequency
Counter
CT-109 or FIF-10/CT-108
T
S
RANSMITTER
ECTION
12
Inline
Wattmeter
ANT
MIC/SP
VX-820
Power Supply
7.5 VDC
COM Port or USB Jack
A
S
LINGMENT
ETUP
Setup the test equipment as shown for transceiver
alignment, apply 7.5 V DC power to the transceiver.
Refer to the drawings above for Alignment Points.
The transceiver must be programmed for use in the
intended system before alignment is attempted. The
RF parameters are loaded from the file during the
alignment process.
In order to facilitate alignment over the complete
switching range of the equipment it is recommend-
ed that the channel data in the transceiver is preset
as the chart below.
C
V
HANNEL
ERSION
BAND-LOW
400.000 MHz
BAND-MID
435.000 MHz
BAND-HIGH
470.000 MHz
The alignment mode is accessed by "Alignment
mode" command from the computer, and the align-
ment tool operates it automatically. During the align-
ment mode, normal operation is suspended. Use the
alignment tool program running on PC.
CT-109 or FIF-10/CT-108
R
S
ECEIVER
ECTION
A
V
D
ERSION
450.000 MHz
480.000 MHz
512.000 MHz
RF
Signal Generator
ANT
MIC/SP
VX-820
Power Supply
7.5 VDC
COM Port or USB Jack
A
S
LINGMENT
ETUP

Advertisement

loading

This manual is also suitable for:

Vx-820e series