Troubleshooting - Bosch Wallscanner D-tect 150 Operating/Safety Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

Batteries empty
Batteries incorrectly inserted (wrong polarity)
Detection tool too warm or too cold
Wheel losing contact with the surface
Detection tool has been moved to quickly
Trouble Shooting
Issue
Detection tool cannot be switched on
Detection tool switched on but does not react
Display indication: "Slipping Wheel"
Display indication: "Speeding"
"Temperature over range"
"Temperature under range"
"Strong radio signal detected"
Replace batteries
Check if the batteries are inserted correctly
Take out batteries and reinsert again
Wait until operating temperature range is reached
Press the start button
bottom wheels have contact with the wall while moving
the detection tool; in case of uneven walls, position a thin
piece of cardboard between the wheels and the wall
Press the start button
slowly over the wall
Wait until operating temperature
range is reached
Wait until operating temperature
range is reached
Detection tool switches off automatically. If possible,
eliminate the interfering radio waves, e.g. WLAN, UMTS,
radar, transmitter antenna or microwaves, then switch the
detection tool on again.
-16-
Remedy
11
and take care that the two
11
and move detection tool

Advertisement

Table of Contents
loading

Table of Contents