D-Link Dis-200G Series Web Ui Reference Manual page 158

Industrial gigabit ethernet switch.
Hide thumbs Also See for Dis-200G Series:
Table of Contents

Advertisement

PoE
Trap Name
pethMainPowerUsageOn
Notification
pethMainPowerUsageOff
Notification
isPoeIfPdAliveFailOccurN
otification
Port
Trap Name
linkUp
linkDown
DIS-200G Series Industrial Gigabit Ethernet Smart Managed Switch
to the Forwarding state, or from the Forwarding state
to the Blocking state. The trap is not sent if a newRoot
trap is sent for the same transition. Implementation of
this trap is optional
Description
This trap indicates PSE Threshold usage indication is
on, the usage power is above the threshold. At least
500 msec must elapse between notifications being
emitted by the same object instance.
Binding objects:
(1) pethMainPseConsumptionPower
This trap indicates PSE Threshold usage indication is
off, the usage power is below the threshold. At least
500 msec must elapse between notifications being
emitted by the same object instance.
Binding objects:
(1) pethMainPseConsumptionPower
This Notification indicates if the PD device has the stop
working or no response problem.
Description
A notification is generated when port linkup.
Binding objects:
(1) ifIndex
(2) ifAdminStatus
(3) ifOperStatu
A notification is generated when port linkdown.
Binding objects:
(1) ifIndex
(2) ifAdminStatus
147
OID
1.3.6.1.2.1.105.
0.2
1.3.6.1.2.1.105.
0.3
1.3.6.1.4.1.171.
11.155.1000.24.
0.4
OID
1.3.6.1.6.3.1.1.5
.4
1.3.6.1.6.3.1.1.5
.3