Mitsubishi Electric MELSERVO MRJ2S-B Instruction Manual page 34

Servo amplifier and motors
Table of Contents

Advertisement

Introduction
Fig. 1-20: Servo amplifier MR-J2S-500B and MR-J2S-700B
No.
Name
Bus cable connector (CN1A)
Bus cable connector (CN1B)
Communication connector
(CN3)
Name plate
Encoder connector (CN2)
Charge lamp
Main circuit terminal block
(TE1)
Control circuit terminal block
(TE2)
Protective earth terminal (PE) Module grounding
Fan
Tab. 1-4: Operating elements and their meaning
b
CAUTION:
Any mixing up of the connectors CN1A, CN1B, CN3 and CN2 can lead to a shortcircuit
and damage to the inputs and outputs.
1 - 16
Description
Used to connect the servo system controller or
preceding axis servo amplifier.
Used to connect the subsequent axis servo
amplifier or termination connector (MR-A-TM)
Used to connect a personal computer or output
analog monitor data.
Used for connection of the servo motor
encoder.
Lit to indicate that the main circuit is charged.
While this lamp is lit, do not reconnect the
cables
Used to connect the input power supply and
servo motor.
Used to connect the control circuit power
supply and regenerative brake option.
Operating elements
S000916C
Reference
Section 3.1.3
Section 3.1.3
Section 3.1.3
Section 1.3.3
Section 3.1.3
Section 3.1.2
Section 3.1.2
Section 3.4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo mrj2s-b4