M
N
AKING
ETWORK
1000BASE-T Cable Requirements
All Category 5 UTP cables that are used for 100BASE-TX connections
should also work for 1000BASE-T, providing that all four wire pairs are
connected. However, it is recommended that for all critical connections, or
any new cable installations, Category 5e (enhanced Category 5) or
Category 6 cable should be used. The Category 5e and 6 specifications
include test parameters that are only recommendations for Category 5.
Therefore, the first step in preparing existing Category 5 cabling for
running 1000BASE-T is a simple test of the cable installation to be sure
that it complies with the IEEE 802.3ab standards.
1000 Mbps Gigabit Ethernet Collision Domain
Table 4-1 Maximum 1000BASE-T Gigabit Ethernet Cable Length
Cable Type
Category 5, 5e, or 6 100-ohm UTP
or STP
Table 4-2 Maximum 1000BASE-SX Gigabit Ethernet Cable Lengths
Fiber Size
62.5/125 micron
multimode fiber
50/125 micron
multimode fiber
Table 4-3 Maximum 1000BASE-LX Gigabit Ethernet Cable Length
Fiber Size
9/125 micron
single-mode fiber
4-8
C
ONNECTIONS
Fiber
Bandwidth
160 MHz/km
200 MHz/km
400 MHz/km
500 MHz/km
Fiber
Bandwidth
N/A
Maximum Cable
Length
100 m (328 ft)
Maximum Cable
Length
2-220 m (7-722 ft)
2-275 m (7-902 ft)
2-500 m (7-1641 ft)
2-550 m (7-1805 ft)
Maximum Cable
Length
2 m - 5 km (7 ft - 3.2
miles)
Connector
RJ-45
Connector
LC
LC
LC
LC
Connector
LC