Yamaha EF7200E Owner's Manual page 32

Hide thumbs Also See for EF7200E:
Table of Contents

Advertisement

Available languages

Available languages

  • ENGLISH, page 1
A
B
4
C
4
D
4
240V
Y
G
120V
W
X
120V
4. Turn the AC switch (N.F.B.) and economy control
4
4 "I" (ON)
å EF7200/EF7200E
∫ AC 120 V can be used. (EF7200DE)
763-252
ç AC 120 V and 240 V can be used. (EF7200DE)
∂ Economy control switch (Except for EF7200)
NOTICE
Reduce the load to the specified generator rated
output if the AC switch (N.F.B.) turns off. If it turns
off again, consult a Yamaha dealer.
4
TIP
9 The 4-blade plug receptacle can supply both
GR
9 The economy control switch must be turned to "3"
- using a load of 0.8 A or less.
- supplying AC 120 V only from W with X.
switch to "I" (ON) and turn on any electric devices.
120 V and 240 V power sources.
(OFF) to increase engine speed to rated r/min
when: