9 If you are installing a Summit7i switch, remove the helper bracket after the chassis is
secured.
10 Connect the Summit switch to the redundant power supply (if applicable).
11 Connect cables.

Free-Standing

The Summit switch is supplied with four self-adhesive rubber pads. Apply the pads to
the underside of the device by sticking a pad in the marked area at each corner of the
switch.

Stacking the Switch and Other Devices

You can place up to four Summit switches on top of one another.
Note: This relates only to physically placing the devices on top of one another.
Apply the pads to the underside of the device by sticking a pad at each corner of the
switch. Place the devices on top of one another, ensuring that the corners align.
Connecting Equipment to the Console Port
Connection to the console port is used for direct local management. The switch console
port settings are set as follows:
• Baud rate — 9600
• Data bits — 8
• Stop bit — 1
• Parity — None
• Flow control — XON/XOFF
The terminal connected to the console port on the switch must be configured with the
same settings. This procedure is described in the documentation supplied with the
terminal.