Download Print this page

Removal Of Sound Blankets - Daikin RKS20G2V1B Service Manual

Removal procedure, 2.0/2.5/3.5 kw class, outdoor unit, inverter, pair type, cooling only, heat pump
Hide thumbs Also See for RKS20G2V1B:

Advertisement

Removal of Sound Blankets

6. Removal of Sound Blankets
Procedure
Step
1
Untie the string and
open the sound blanket
(outer).
2
Lift and remove the
sound blanket (outer).
Remove the sound
3
blanket (top).
4
Pull the sound blanket
(inner) out.
18
Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Sound blanket (outer)
Sound blanket
(top)
Sound blanket (inner)
Points
Preparation
Remove the outer panels
according to the "Removal of
Outer Panels / Fan Motor".
Remove the electrical box
according to the "Removal of
Electrical Box".
The design of the sound
blankets varies depending
on the model.
(R7229)
Since the piping ports are
torn easily, remove the
sound blanket carefully.
(R12212)
(R7231)
(R12271)
Removal Procedure
Si00-872

Hide quick links:

Advertisement

loading