Removal Of Air Filters / Front Panel - Daikin FTXS15HVJU Service Manual

Removal procedure, 15000/18000/24000 btu/h class
Hide thumbs Also See for FTXS15HVJU:
Table of Contents

Advertisement

Removal of Air Filters / Front Panel

1. Removal of Air Filters / Front Panel
Procedure
Step
1. Appearance features
2. Remove the air filters.
1
Open the front panel to
the position where it
stops.
Lift the air filter upward
2
slightly by the center
knob, and then pull it
out downward.
2
Warning
Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Procedure
Timer lamp
[ON/OFF] button
Front panel
Air filter
Room temperature sensor
(thermistor)
(R5323)
Operation lamp
Signal
receiver
(R15466)
(R5325)
(R5326)
Si04-955
Points
Warning
Dangerous: High voltage
A high voltage is applied to all
the electric circuits of this
product including
thermistors.
When the signal receiver
catches a signal from the
remote controller, the
receiving tone sounds and
the operation lamp blinks
immediately to confirm the
signal reception.
When the [ON/OFF] button
is kept pressed for 5
seconds, the forced cooling
operation is performed for
about 15 minutes.
The air filter is not marked
for difference between the
right and left sides.
Insert the air filter with the
"FRONT" mark faced up.
The air filter can be set
easily by inserting it along
the guides.
Be sure to insert the hooks
(at 2 lower positions) when
mounting the air filter.
Removal Procedure

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ftxs24hvjuFte18jv2sFte24gv2sFtxs18hvju

Table of Contents