Horizontal Blades / Vertical Blade Assys - Daikin FTKD25GVM9 Service Manual

Removal procedure, 2.0/2.5/3.5 kw class, 9000/13000 btu/h class
Table of Contents

Advertisement

Si041251EC

4. Horizontal Blades / Vertical Blade ASSYs

Warning
Step
1. Remove the horizontal
blades.
Unfasten the center
1
shaft while bending the
horizontal blade (upper)
slightly.
Unfasten the left shaft.
2
Unfasten the right shaft.
3
Remove the horizontal
4
blade (lower) in the
same way.
Removal Procedure
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Horizontal Blades / Vertical Blade ASSYs
(R4329)
(R4330)
Key alignment
(R4331)
Points
When reassembling, mount
the large horizontal blade to
the upper position and the
small horizontal blade to the
lower position.
Do not install them in the
wrong place.
Installation procedure
1. Since the key pattern hook
is provided, rotate the blade
and fit it to the right shaft
first.
2. Fit the blade to the center
and left shafts.
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents