Fan Rotor - Daikin FTKD25GVM9 Service Manual

Removal procedure, 2.0/2.5/3.5 kw class, 9000/13000 btu/h class
Table of Contents

Advertisement

Fan Rotor

10.Fan Rotor
Warning
Step
Remove the 2 screws
1
of the right side plate.
2
Release the fan motor
lead wire from the
hooks and remove the
right side plate.
3
Remove the 2 screws
of the fan motor fixing
plate.
4
Unfasten the hook (a)
of the fan motor fixing
plate and unfasten the
hook (b).
5
Remove the fan motor
fixing plate.
Loosen the screw and
6
remove the fan motor
and the fan rotor.
20
Be sure to wait for 10 minutes or more after turning off all power supplies before
disassembling work.
Procedure
Fan motor lead wire
Fan motor
Fan rotor
Hook
Right side plate
(R17212)
Fan motor
fixing plate
Hook (b)
Hook (a)
(R17929)
Screw
(R19302)
Si041251EC
Points
When reassembling the fan
motor and the fan rotor,
provide as much as 5 mm
(0.2 inch) of play between
the side face of the rotor and
the bottom frame.
Side face of
Side face of rotor
bottom frame
5 mm (0.2 inch)
(R9582)
(1) Insert the fan motor with
approx. 5 mm (0.2 inch) left.
(2) Tighten the screw until it
stops. Then give the screw
one more turn.
(3) Rotate the fan rotor and
confirm the fan motor and
the fan rotor are installed
appropriately.
(4) Tighten the screw
completely if appropriate.
(5) If not appropriate, go back to
(1).
Removal Procedure
(R18879)