Absolute pressure input
Measured variable
Span (continuously
adjustable) or measuring
range, max. operating
pressure (in accordance
with 97/23/EC Pressure
Equipment Directive) and
max. test pressure (in
accordance with
DIN 16086)
Gauge pressure input, with flush-mounted diaphragm
Measured variable
Span (continuously
adjustable) or measuring
range, max. operating
pressure and max. test
pressure
Absolute pressure input, with flush-mounted diaphragm
Measured variable
Span (continuously
adjustable) or measuring
range, max. operating
pressure (in accordance
with 97/23/EC Pressure
Equipment Directive) and
max. test pressure (in
accordance with
26
HART
Absolute pressure
Span
Maximum
operating
pressure
MAWP (PS)
8 ...
1.5 (22 psi a)
250 mbar a (3
... 100 inH
O)
2
43 ...
2,6 bar a
1300 mbar a
(38 psi a)
(17 ...
525 inH
O)
2
0.16 ...
10 bar a
5 bar a (2.3
(145 psi a)
... 73 psi a)
1 ... 30 bar a
45 bar a
(14.5 ...
(653 psi a)
435 psi a)
HART
Gauge pressure
Span
Maximum
operating
pressure
MAWP (PS)
0.01 ...
4 bar g
1 bar g (0.15
(58 psi g)
... 14.5 psi g)
0.04 ...
7 bar g
4 bar g (0.58
(102 psi g)
... 58 psi g)
0.16 ...
21 bar g
16 bar g (2.3
(305 psi g)
... 232 psi g)
0.63 ...
67 bar g
63 bar g (9.1
(972 psi g)
... 914 psi g)
Depending on the process connection, the span may deviate from these values.
HART
Absolute pressure
Span
Maximum
operating
pressure
MAWP (PS)
43 ...
2.6 bar a
1300 mbar a
(38 psi a)
(17 ...
522 inH
O)
2
PROFIBUS PA or Foundation Fieldbus
Maximum test
Measuring
pressure
range
6 bar a
250 mbar a
(87 psi a)
(3.6 psi a)
10 bar a
1.30 bar a
(145 psi a)
(19 psi a)
30 bar a
5 bar a
(435 psi a)
(73 psi a)
100 bar a
30 bar a
(1450 psi a)
(435 psi a)
PROFIBUS PA or Foundation Fieldbus
Maximum test
Measuring
pressure
range
6 bar g
1 bar g
(87 psi g)
(14.5 psi g)
10 bar g
4 bar g
(145 psi g)
(58 psi g)
32 bar g
16 bar g
(464 psi g)
(232 psi g)
100 bar g
63 bar g
(1450 psi g)
(914 psi g)
PROFIBUS PA or Foundation Fieldbus
Maximum test
Measuring
pressure
range
10 bar a
1300 mbar a
(145 psi a)
(522 inH
SITRANS P300 (7MF8.23.. 7MF8.24.. 7MF8.25..)
Maximum
Maximum test
operating
pressure
pressure
1.5 bar a
6 bar a
(22 psi a)
(87 psi a)
2.6 bar a
10 bar a
(38 psi a)
(145 psi a)
10 bar a
30 bar a
(145 psi a)
(435 psi a)
45 bar a
100 bar a
(653 psi a)
(1450 psi a)
Maximum
Maximum test
operating
pressure
pressure
4 bar g
6 bar g
(58 psi g)
(87 psi g)
7 bar g
10 bar g
(102 psi g)
(145 psi g)
21 bar g
32 bar g
(305 psi g)
(464 psi g)
67 bar g
100 bar g
(972 psi g)
(1450 psi g)
Maximum
Maximum test
operating
pressure
pressure
2.6 bar a
10 bar a
O)
(38 psi a)
(145 psi a)
2