Ssb Replacement Flowchart - Philips 32PFL7403D/10 Service Manual

Chassis q528.2e lb. me8+
Hide thumbs Also See for 32PFL7403D/10:
Table of Contents

Advertisement

5.8.5
SSB Replacement
Follow the instructions in the flowchart in case you have to
exchange the SSB. See figure "SSB replacement flowchart".
Set is starting up but no display .
Update main software in this step, by using
"autorun.upg" file.
Program "Display Option" code via 062598
MENU, followed by 3 digits code (this code
can be found on a sticker inside the set).
After entering "Display Option" code, set is
going to Standby (= validation of code).
Restart the set.
Connect PC via ComPair interface to Service
connector.
Start TV in Jett mode (DVD i+ (OSD))
Open ComPair browser Q 52x.
Program "set type number" , "serial number",
and "display 12NC".
Service Modes, Error Codes, and Fault Finding
Create "repair" directory on USB stick and
connect USB stick to TV-set
Go to SAM mode and save the TV settings
via "Upload to USB".
- Replace SSB board by a Service SSB.
- Make the SSB fit mechanically to the set.
Start-up set.
Set behaviour?
Set is starting up & display is OK .
Saved settings
No
on USB stick?
Go to SAM mode, and reload settings
via "Download from USB".
If not already done;
Check latest software on Service website.
Update Main and Standby software via USB.
Check and perform alignments in SAM
according to the Service Manual.
E.g. option codes, colour temperature...
Final check of all menus in CSM.
Special attention for HDMI Keys.
Figure 5-15 SSB replacement flowchart
START
Set is still
operating?
Set is starting up in "Factory" mode .
Noisy picture with bands/lines is visible and the
Press 5 s. the "Volume minus" button on the local
cntrl until the red LED switches "off", and then
press 5 s. the MENU button of the local cntrl.
The picture noise is replaced by blue mute!
Program "Display Option" code via 062598 MENU,
followed by 3 digits code (this code can be found
After entering "Display Option" code, set is going
Yes
END
Q528.2E LB
No
red LED is continuous "on"
(sometimes also the letter "F" is visible ).
Unplug the mainscord to verify the correct
disabling of the factory-mode.
on a sticker inside the set ).
to Standby (= validation of code).
Restart the set.
In case of settings reloaded from USB , the set type ,
serial number , Display 12NC, are automatically stored
when entering display options .
- Check if correct "Display Option" code is programmed .
- Verify "Option Codes" according sticker inside the set
- Default settings for White drive ...see Service Manual
Q52xE SSB Board swap – v3
VDS/JA Updated 17-10-2008
5.
EN 39
.
H_16771_007.eps
171008

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents