Download Print this page

BEA Falcon Installation Manual page 3

Motion sensors for industrial doors and gates

Advertisement

MOUNTING TIPS
Avoid vibrations.
DIMENSIONS (inches)
Wall mounting
POSSIBLE SETTINGS BY REMOTE CONTROL
FIELD SIZE
HOLD-OPEN TIME
OUTPUT
CONFIGURATION
DETECTION MODE
DETECTION FILTER
FACTORY VALUES
POSSIBLE SETTINGS BY PUSH BUTTONS
TO START OR END AN ADJUSTMENT SESSION, press and hold either push button until the LED flashes or
stops flashing.
TO SCROLL THROUGH THE
PARAMETERS, press
the right push button.
TO CHANGE THE VALUE OF
THE CHOSEN PARAMETER,
press the left push button.
TO RESET TO FACTORY VALUES, press and hold both push buttons until both LEDs flash.
75.5835.04 FALCON FAMILY 20160301
Do not cover the sensor.
Ceiling mounting
Ceiling mounting
XXS
XS
S
0.5 s
1 s
2 s
A
P
bi
uni
1
2
RESETTING TO FACTORY VALUES:
1 FIELD SIZE
2 HOLD-OPEN TIME
3 OUTPUT CONFIGURATION
4 DETECTION MODE
5 DETECTION FILTER
Avoid proximity to neon
lamps or moving objects.
>
>
>
3 s
4 s
5 s
uni
AWAY
5
3
4
Parameter n°
Only open the sensor
when the cable needs
to be replaced.
Bracket dimensions
Bracket dimensions
>
L
XL
XXL
6 s
7 s
8 s
9 s
A = active output (relay active when detection)
P = passive output (relay active when no detection)
bi = two-way detection
uni = one-way detection towards sensor
uni AWAY = one-way detection away from sensor
6
Value (factory values)
(7)
(0)
(1)
(2)
(1)
Page 3 of 4

Advertisement

loading

This manual is also suitable for:

Falcon xlFalcon wide