Stoelting E122 Operator's Manual page 21

Counter top shake or frozen beverage freezer
Table of Contents

Advertisement

Figure 3-8 F122 Condenser Filter Removal
F122 Air Cooled Condenser Cleaning
A.
Remove the Phillips head screws from the right
side panel, and then remove the panel.
B.
To remove the condenser fi lter, grasp the top and
pull off. Visually inspect for dirt. If the fi lter is dirty,
shake or brush excess dirt off the fi lter and wash
in warm, soapy water. Once the fi lter is clean rinse
thoroughly in warm, clear water and shake dry,
taking care not to damage the fi lter in any way.
C.
Visually inspect the condenser for dirt by shining
a light through the coil from the back (inside) of
the condenser.
D.
If the condenser is dirty, place a wet towel over
the front (outside) of the condenser.
E.
Using a vacuum, carefully clean the condenser
coil from the inside and outside of the machine.
A stiff bristled brush may help in releasing debris
from between the condenser coils.
E. SEMI-ANNUALLY
1.
Disconnect the machine from the power source.
2.
Check drive belt for proper tension. Push belt in
with one fi nger, belt should defl ect about 3/8".
3.
Lubricate condenser fan motor with S.A.E. 20
weight oil. Three to six drops is required.
4.
Sanitize the autofi ll system following the steps
below:
Owner's Manual #513667
AUTOFILL SANITIZING
A.
If necessary, disassemble, clean and sanitize the
machine.
If the machine does not require cleaning and sani-
tizing, press the Pump On/Off button to turn off the
pump. Then dispense enough product so that the
mix level in the hopper is below the long probe. If
the mix level is above the long probe, the solenoid
will not activate and the pump will not operate.
B.
Prepare Stera-Sheen Green Label Sanitizer
or equivalent according to manufacturer's
instructions to provide a 100ppm strength solution.
Mix the sanitizer in quantities of no less than 2
gallons of 90° to 110°F (32° to 43°C) water. Any
sanitizer must be used only in accordance with
the manufacturer's instructions.
C.
Cut an adapter from an empty bag of syrup.
Connect the adapter to the BIB connector of the
syrup line. Put the BIB connector into the bucket
of sanitizer.
If you do not have an empty bag of syrup, remove
the plug from the top of the BIB connector. Do not
lose the plug; it is needed for proper operation of
the BIB.
D.
Make sure the display screen shows that the
main power is on. Hold the hopper cover over a
bucket and press the Pump On/Off button. The
solenoid will activate and the brix pump will pump
sanitizer into the bucket.
The solenoid will only activate when there is not any
liquid touching the longer mix probe in the hopper.
E.
After all the sanitizer has run through the pump,
press the Pump On/Off button to turn off the pump.
F.
Disconnect the bag adapter from the BIB connector
(or reinsert the plug into the connector). Connect
the BIB connector to the syrup BIB.
G.
Hold the hopper cover over a bucket and press the
Pump On/Off button. This will fl ush the sanitizer
out of the pump and tubing. Once the sanitizer
is fl ushed out, press the Pump On/Off button.
H.
The pump is now ready to operate. Place the
hopper cover on the hopper.
15
NOTE
NOTE
NOTE
E122 & F122 Model Machines