Dip Switch
Will not be used. Turn every dip switch OFF.
Operating conditon displaying LED
LED Display
Green lights on
Red lights on
Interface Connector
This connector connects the R/W module to a User Board.
Antenna Section
When communicating with the Tag, please bring the Tag close to the antenna
section.
(2)
General Specifications
Item
External measurement
Installation
Electric current
Dissipation current
Vibration resistance
Shock resistance
Ambient temperature
during use
Ambient temperature
during storage
Ambient humidity
during use
Radio frequency
Transmission distance
(Tag: V700 - D13P31)
Distance at center of
coil - Tag axis
Lights on when communicating with the Tag
Lights on when communication process does not complete
successfully.
Board Type (L)
80 × 80 × 5 mm
4 points Secured by
M3 screws
5V ±10%
180 mA or less (during oscillation)
20 mA or less (no oscillation)
2
Destruction: 20m/s
10 to 150Hz, 0.15mm double
amplitude, with 4 sweeps of 8min each in 3 directions
2
Destruction: 200m/s
, 3 times each in 6 directions
-10 ~ +55°C
-25 ~ +65°C
25 ~ 85% RH or less (with no condensation)
125 kHz
5 ~ 65 mm
Detail
Board Type (S)
40 × 44 × 10 mm
Secured at 3 points,
M2 or M2.3 screws
10 ~ 40 mm