2)
Single Auto
After receiving command, the Module waits for the Tag to approach,
communicates with the Tag, and then transmits a response. Once the
response is transmitted, Module will be on stand by for new commands.
During communication with the Tag, there must be one Tag within the
communication area.
♦ Operation Sequence
After receiving command, the Module waits for the Tag to approach, then
executes process once only after Tag is detected. When Module receives a
STOP command, the command will be completed.
User →
Command
User ←
Tag
Communication
Tag
Tag Operation
Detection
3)
FIFO Trigger
Module will communicate with Tag immediately after receiving command
and transmit response. After communication is completed, Module will
prohibit Tag from operating. Module will be on stand by for commands after
response is transmitted. During communication with Tag, there MUST BE
AN OPERATIONAL TAG (A TAG THAT IS NOT PROHIBITED FROM
OPERATION) within the communication area. When this command is
executed, Module automatically activates "Oscillation Mode"
♦ Operation Sequence
Upon receiving command, Module will execute process once only. If there
is no Tag, a Tag absence error will be transmitted. During processing of the
command, Tag will become inoperative, and thus will not respond to the
next command. Oscillation will continue after command is processed.
User →
Command
User ←
Tag
Communication
Command Process
Tag Operation
Response
Command Process
Tag 1
Command
Response 1
(Oscillation)
Command Process
Tag 1
Command
STOP
Tag Detection
Response 2
(Tag Absence Error)
(Oscillation)
(12/23)