Installation

Sensing Head

1.
With the flowmeter housing installed, mount the ILE-61 to a rigid support structure.
2.
Remove the ILE-61 fibreglass cover. With the outer gasket in place, bolt the ILE-61 to
the housing.
3.
Adjust the sensing head leveling hardware (provided) to establish level in both
horizontal planes.
Note:
Ensure the sensing head mounting structure is capable of supporting the
dynamic material impact forces as well as the weight of the sensing head.
rigid support

Sensing Plate

1.
Open the flowmeter housing access door.
2.
With the sensing head cover removed, remove the taper pin.
3.
Insert the sensing plate shaft fully into the sensing head socket.
Note:
Ensure the sensing plate shaft is installed with the flat side up.
4.
Insert the taper pin (flat side down), from the left side.
5.
Tighten the right taper pin nut to lock the sensing plate shaft in place.
6.
Tighten the left taper pin nut.
taper pin
(flat side down)
Page 4
spirit level
Milltronics ILE-61 – INSTRUCTION MANUAL
moving beam
(machined
surface)
shaft
socket
flat side up
7ML19985CX01