Maintenance and Spare Parts

Maintenance

A program of routine maintenance should be established to ensure the highest
achievable level of performance is maintained. Good housekeeping practices in the area
of the flowmeter are recommended.
Maintenance Description
Clean area around flowmeter
Check sensing place surface*
Check damping fluid
Check sensing head inner gasket
Check sensing plate wear
Check test weight Rate display
Test flowmeter linearity
* Material buildup (if any) in the impact area of the sensing plate should be
removed.

Spare Parts

Milltronics recommends a spare inner and outer gasket, sensing plate, and spare
damping fluid be kept on hand.
Contact Milltronics or your distributor for spare parts ordering information.

Unit Repair and Excluded Liability

All changes and repairs must be done by qualified personnel and applicable safety
regulations must be followed. Please note the following:
The user is responsible for all changes and repairs made to the device.
All new components must be provided by Siemens Milltronics Process
Instruments Inc.
Restrict repair to faulty components only.
Do not re-use faulty components.
7ML19985CX01
Regular
!
!
Milltronics ILE-61 – INSTRUCTION MANUAL
Frequency
Monthly
Semi-Annual
!
!
!
!
!
!
!
!
!
!
!
Annual
!
!
!
!
!
!
!