Advertisement

Neets Control – SieRRa II
SieRRa II EU P/N: 310-0102
SieRRa II DK P/N: 310-0202
SieRRa II US P/N: 310-0402
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for Neets SieRRa II 310-0102

  • Page 1 Neets Control – SieRRa II SieRRa II EU P/N: 310-0102 SieRRa II DK P/N: 310-0202 SieRRa II US P/N: 310-0402 User Manual...
  • Page 2: Foreword

    COPYRIGHT - All information contained in this manual is the intellectual property of and copyright- ed material of Neets. All rights are reserved. You may not allow any third party access to content, information or data in this manual without Neets’ express written consent.
  • Page 3: Important Safety Instructions

    Contact your local Neets reseller or distributor. • If the equipment has slots or holes in the enclosure, these are provided to prevent overheating of sensitive components inside.
  • Page 4: Table Of Contents

    Contents Foreword ............. . 2 Revision list .
  • Page 5: Description

    SieRRa II can control devices through IR, RS232 or even LAN. SieRRa II is available in polar white and anthracite. The drawings in the manual of Neets Control - SieRRa II is based on the DK, US and EU versions. Function description...
  • Page 6: Quick Guide To The Sierra Ii

    TX-1 TX-3 TX-1 TX-2 TX-2 TX-3 TX-2 TX-3 Neets Control - SieRRa II, US P/N#: 310-0402 Neets Control - Sierra II, DK P/N#: 310-0202 Number: Description 1 x 12 VDC power input 1 x RS-232 port, Bidirectional or IR Unidirectional...
  • Page 7: Installation

    Installation The Neets Control - SieRRa II can be installed in standard electrical back boxes or by using mount- ing brackets. Each model (DK, US, EU) fits in typical boxes matching specific installation require- ments for the country of sale.
  • Page 8 Note that the front cover mounts in only one direction. Paper label Transparent label Front cover Connect and apply power to the control system. Configure the control system using the Neets Project Designer. Page 8 of 13...
  • Page 9: Connections And Controls

    TX-2 Note: If using the PoE functionality to power the TX-3 SieRRa II, do not connect the AC power adaptor. Neets Control - Sierra II, DK P/N#: 310-0202 I/O ports The three I/O (Inputs/Outputs) can be configured as Relay control either output or input.
  • Page 10: Neb Port

    GND, as shown above. Use Neets IR-Emitter Use Neets IR-Emitter NEB port The SieRRa II has a built-in NEB (Neets Exten- sion Bus). This port is used to add up to 5 NEB devices (e.g. two Keypads, two Level Controls and one Expander).
  • Page 11: Lan Port

    PC 2 light to indicate current status of the AV system. SCREEN Button function and LED indication are set up using the Neets Project Designer software. Configuration through USB port The USB port is used exclusively for configuring the SieRRa II from the Neets Project Designer software.
  • Page 12: Troubleshooting

    Flashing Flashing Flashing Error in serial You need to return the unit to Neets or your local dealer for number replacement/repair. Flashing Resuming factory default When pressing Switch 1 and 4 during power on, the system...
  • Page 13: Specifications

    Specifications Power input Input voltage 12 VDC Output type Open drain Power Usage Isolated output Connector 2 pin screw block Max voltage load 24 VDC Max current 0.5 A Power adaptor (included) Connector 4 pin screw block Input voltage 100 VAC – 240 VAC Network (LAN) Line frequency 50 Hz –...

This manual is also suitable for:

Sierra ii 310-0202Sierra ii 310-0402

Table of Contents