OPERATION AND APPLICATION
The total macro memory requirements can be calculated by summing the
memory for each individual macro. For example, suppose that you use one
macro to connect secondary #7, another macro to issue a Primitive 45 bytes long
expecting a response 30 bytes long, and another macro to disconnect secondary
#5. The total memory required for these three macros is:
Macro #1, Connect
Macro #2, Primitive
Macro #3, Disconnect
Total Memory Required
Example 2–2 Macro Memory Requirements
Host
Computer
UniLink Host Adapter
Figure 2–15 Host Computer Multiprocessing Application
= 22
= 22 + 45 + 30
= 22
= 22
142 Bytes