Technical data chapter. Use this information
in conjunction with the length of run, number
of elbows, tees and bends, the available
service pressure and the supply
requirements of other installed appliances
to determine a suitable pipe size. For
assistance in this matter refer to the
appropriate section of AS/NZS 5601.1 or
AS/NZS 5601.2.
An AGA certified class B or D flexible
connection can be used to connect the
cooktop in accordance with AS/NZS
5601.1, in particular section 5.9 and clause
6.10.1.8, or AS/NZS 5601.2, in particular
section 2.11. Where a hose assembly is
used and the cooktop is in the installed
position, the hose assembly shall be
suitable for connection to a fixed consumer
piping outlet located at a point 800 –
850mm above the floor and in the region
outside the width of the appliance to a
distance of 250mm. The point of connection
to consumer piping must be accessible with
appliance installed.
Be careful the hose does not come in touch
with mobile parts or is not squeezed. Also
be careful when the hob is put together with
an oven. Ensure that the hose assembly is
restrained from accidental contact with the
flue outlet of an underbench oven or any
other hot surface of an adjacent appliance.
Regulator
The regulator must be positioned that the
pressure test nipple is accessible when the
appliance is installed. Connect the gas
supply to the ½ B.S.P. internal thread inlet
of the regulator.
A. Outlet
B. Inlet
Assembly of regulator
To connect the regulator to the cooktop use
the elbow and washer supplied with the
appliance.
The ½" parallel thread connects to the end
of shaft with nut. The washer is placed
between the end of shaft and the elbow.
The ½" tapered thread connects to the
outlet of the regulator, and is sealed on the
thread. Use thread sealing tape or thread
sealing compound.
The inlet of the regulator is a ½" parallel
thread and is connected to consumer piping
or hose assembly.
The regulators are configured for
use with Natural Gas. It is not
required to adjust the regulator
to obtain correct outlet pressure
setting.
When the inlet and outlet is
orientated correctly the arrow on
the base of the regulator
indicates the direction of gas
flow.