The Model SLIM Loop Isolator Module from Siemens Building Technologies, Ltd.
isolates short circuits on FS-250C analog loops. By placing devices between SLIMs
during installation, a short in the wiring within that group is disconnected from the
rest of the loop. The
remainder of the devices
continue to operate. The
SLIM operates in both
Class A and Class B
circuits.
A yellow LED flashes
when a device detects a
short circuit. The SLIM
then isolates that part of
the loop. When the short
is removed, the SLIM
automatically restores
the loop to normal operation. The SLIM does not have a loop address and therefore
does not require address programming nor does it reduce the loop capacity below
252 devices.
Remove all system power before installation, first the battery and then the AC.
The SLIM is a polarity insensitive module. Refer to Figure 1 for the location of the two
input terminals and two output terminals. Line 1 and Line 2 can be either line of the
loop.
The SLIM may be used in two circuit configurations as follows:
(See Figure 2) In Class B wiring each SLIM isolates a branch on the circuit. Note that
a short on the main branch causes the entire loop to fail. To prevent this, mount the
SLIMs at the enclosure and run each branch independently.
FRONT
FAULT
Figure 1
The SLIM-1 Loop Isolator Module
Siemens Building Technologies
BACK
IN - LINE 1
IN - LINE 2
OUT - LINE 1
OUT - LINE 2
Fire Safety

Advertisement

loading

Summary of Contents for Siemens SLIM

  • Page 1: Installation Instructions

    Remove all system power before installation, first the battery and then the AC. INSTALLATION The SLIM is a polarity insensitive module. Refer to Figure 1 for the location of the two input terminals and two output terminals. Line 1 and Line 2 can be either line of the loop.
  • Page 2 7 . Refer to FDLC Installation Instructions, P/N 315- 447360FA or the FS-250C Figure 3 Manual, P/N 315-049589C SLIM Wiring Diagram - Class A Installation (Single Loop) for the list of compatible devices, as applicable. 8. All terminals are power limited.
  • Page 3 Use a standard 3 1/2-inch deep, double gang electrical switchbox or a 4-inch square electrical box that is 2 1/8 inches deep. • Connect the field wiring. Press the SLIM into the box and fasten the module plate to the box. •...
  • Page 4 Siemens Building Technologies, Ltd. 2 Kenview Boulevard Brampton, Ontario L6T 5E4 P/N 315-049692C-1...