• F51 transceivers are rated for -40 to 85 °C (-40 to 185 °F).
Connector
RJ45
RJ45
e
Auto-Negotiating
f
Shielded or unshielded.
g
Auto-crossover and auto-polarity.
h
Typical distance. Dependent on the number of connectors and splices.
i
RMS 1 minute.
Section 5.5

Fiber Optic Ethernet Port Specifications

The following details the specifications for fiber Ethernet ports that can be ordered with the RUGGEDCOM
RSG2300.
10FL Ethernet Optical Specifications
Connector
Mode
Type
MM
ST
MM
ST
j
Typical.
k
Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens
sales associates when determining maximum distances.
Fast Ethernet (10/100 Mbps) Optical Specifications
Connector
Mode
Type
MM
ST
MM
ST
MM
ST
MM
ST
MM
SC
MM
SC
MM
MTRJ
MM
MTRJ
Fiber Optic Ethernet Port Specifications
Speed
Duplex
10/100 Mbps
FDX/HDX
1000 Mbps
FDX/HDX
Cable
Tx λ (nm)
Type (µm)
62.5/125
850
50/125
850
Cable
Tx λ (nm)
Type (µm)
62.5/125
1300
50/125
1300
62.5/125
1300
50/125
1300
62.5/125
1300
50/125
1300
62.5/125
1300
50/125
1300
e
f
Cable Type
> CAT-5
TIA/EIA T568A/B
> CAT-5
TIA/EIA T568A/B
Tx (dBm)
j
Minimum
Maximum
-16
-9
-19.8
-12.8
Tx (dBm)
l
Minimum
Maximum
-19
-14
-22.5
-14
-19
-14
-22.5
-14
-19
-14
-22.5
-14
-19
-14
-22.5
-14
Technical Specifications
Wiring
Maximum
g
Standard
Distance
100 m (328 ft)
100 m (328 ft)
Rx
Rx
Sensitivity
Saturation
(dBm)
(dBm)
-34
-11.2
-34
-11.2
Rx
Rx
Sensitivity
Saturation
(dBm)
(dBm)
-31
-14
-31
-14
-31
-14
-31
-14
-31
-14
-31
-14
-31
-14
-31
-14
Chapter 5
i
Isolation
h
1.5 kV
1.5 kV
Power
Distance
Budget
k
(km)
(dB)
2
18
2
14.2
Power
Distance
Budget
m
(km)
(dB)
2
12
2
8.5
2
12
2
8.5
2
12
2
8.5
2
12
2
8.5
31