4. To facilitate the removal of the spill trays, depending on
model, remove the (3) or (4) T-20 Torx stainless screws
in the front face of the included Flush Island Trim.
5. Disconnect the igniter.
A.) Disconnecting a Two Piece Igniter
1) Carefully pull up on the burner base.
Electrode
Ignitor Housing
Ignitor Wire
B.) Disconnecting a Single Piece Igniter
1) Carefully pull up on the burner base.
2) Disconnect the female terminal on the spark wire
from the male terminal on the electrode for each
burner.
IMPORTANT: The locking tab on the female
connector must be depressed to release from the
terminal on the electrode.
Electrode
Burner Base
Burner Base
Ignitor Wire
6. From each burner pedestal, remove the burner
pedestal screws with a T-30 Torx screwdriver.
Burner Pedestal
Burner Pedestal
Burner Pedestal
7. Carefully remove the burner pedestal and the venturi.
8. Remove the spill trays by rotating the trays up and out
the back.
9. Remove the heat shield, on some models. Some
models have a double-width shield that extends under
adjacent spill tray.

Regulator Conversion

The gas regulator is located in the cooktop, left side of
appliance. Exact location will vary per model.
Venturi
English 3