Output Checking Method - Brother BAS-326G Service Manual

Direct drive programmable electronuc pattern sewer
Hide thumbs Also See for BAS-326G:
Table of Contents

Advertisement

2. FUNCTION SETTINGS

2-9. Output checking method

Use this to check for any malfunctions of the circuit boards, and for checking for problems with drive mechanisms and
broken cords.
You can check whether the signals being output by the CPU are driving the mechanisms correctly.
2nd step
PROGRAM No. display
Check code
[ 51]
[ 52]
[ 53]
[ 54]
[ 55]
[ 56]
[ 57]
[ 58]
[ 59]
[ 60]
*1 Applies for pneumatic specifications when corresponding devices are installed.
20
4567Q
4441Q 4953Q
Menu display
Name
When the
[PM-X]
When the
When the
[PM-y]
When the
When the
[PM-F]
When the
When the
[CAtH]
When the
[Option compatibility]
[CL-r]
Right clamp valve turns on. (OUT16) (*1)
[CL-L]
Left clamp valve turns on. (OUT15) (*1)
[Foot]
Intermittent presser foot valve turns on. (OUT14) (*1)
[FLiP]
Inner clamping device valve turns on. (OUT13) (*1)
[CooL]
Needle cooler valve turns on. (OUT12) (*1)
The panel LEDs illuminate in order, and then the seven segments of the
PROGRAM No. display and the menu display illuminate one by one.
BAS-311G, BAS-326G
1. While pressing the
* Keep pressing the
displayed and the buzzer beeps once.
The check code will be displayed in the PROGRAM No.
display (2), and the abbreviated name of the output will
be displayed in the menu display (3).
2. Press the
key (4) or
check code.
3. The operations for check codes 51 to 54 can be
checked by pressing the
4. For check codes 55 and onward, depress the foot
switch to the 2nd step.
(If using a two-pedal foot switch, lower the work clamp
before depressing the start switch (6). )
The corresponding operation for the check code will
be carried out while the foot switch is being
depressed (while the foot switch has been depressed
once for check code 60).
5. To return to normal operation, turn off the power switch
and then turn it back on again.
Operating details
key is pressed, the work clamp moves to the left.
key is pressed, the work clamp moves to the right.
key is pressed, the work clamp moves forward.
key is pressed, the work clamp moves back.
key is pressed, the work clamp lifts.
key is pressed, the work clamp drops.
key is pressed, the thread nipper moves to the home position.
key is pressed, the thread nipper moves to the retract position.
key (1), turn on the power switch.
key (1) until the model name is
key (1) to select the desired
or
key (5).

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Bas-311g

Table of Contents