Statistical Data

Culligan MVP Control Statistic Functions

The Culligan MVP control has the ability to provide statistical information about the system. This data is accessed through
the Statistics key. To move through the statistical data available, use the "-" key. Each push of the "-" key will display new
information. The following table briefly defines the data available while in this mode. The actual data to be displayed will
depend on your type of system (for example, flow data is only show on units utilizing a flow meter).
Display One
44
Culligan® CSM Series Filters
Display Two (Example)
None
None
None
Display Description
Flow rate of water passing through the unit. Display 1 will be shown
for 2 seconds followed for 10 seconds by Display 2. It will repeat this
cycle as long as the "-" or Statistics key(s) are not pressed. Flow rate
is determined using the following formula: Pulses per minute/ "K" factor
per unit = Displayed Flow Rate.
NOTE
The MASTER unit will display the total system flow of
all online units.
Capacity Remaining - The capacity remaining in the batch before
regeneration will be initiated. The display will show Display 1 for 2
seconds then show the remaining capacity (Display 2) for 10 seconds.
It will repeat this cycle as long as the "-" or Statistics key(s) are not
pressed.The X10 or X100 icon shall also be illuminated (depending on
DIP switch 2).
Total Flow Since Installation - The flow totalizer. This shows the total
amount of water that has passed through the individual unit since the
unit was installed. Display 1 will be shown for 2 seconds followed by
the total flow data (Display 2) for 10 seconds. The X10 or X100 icon
shall also be illuminated (depending on DIP switch 2).
Number of Regenerations in the Last 14 Days - Display 1 will il-
luminate for 2 seconds followed by the number of regenerations that
the unit has completed in the last 14 days (Display 2) for 10 seconds.
The controller will not count regenerations if stepped past the last cycle
manually.
Number of Days Since Last Regeneration - Display 1 will illuminate
to indicate the number of days that have passed since the last regen-
eration was completed. There is no Display 2. The controller will not
count regenerations if stepped past the last cycle manually.
Total Number of Regenerations for Life of Unit - Display 1 will illu-
minate for 2 seconds followed by the number of regenerations that the
unit has completed since it was installed (Display 2) for 10 seconds.
Current Day of Week - If operating as a single unit and the unit is
programmed to regenerate on a specific day of the week, Display 1
will illuminate for 2 seconds followed by the current day of the week
(Display 2).
Last Slow Rinse Time - If operating with an Aqua-Sensor Display 1
will illuminate and indicate the number of minutes of the last slow rinse
cycle as controlled by the Aqua-Sensor device.
# Connected Units - The display indicates the number of controls in
the system. It will only be displayed if ID#'s have been assigned and
saved in EEPROM, if DIP switch 9 is ON or if the control is the MAS-
TER unit in a multiple control system.
Progressive Flow Trip Point - This shows the programmed trip point
for the progressive flow feature only in a MASTER unit. Display 1 will
be shown for 2 seconds followed by the trip point in flow units per min-
ute (Display 2).
44
Cat. No. 01016449