8
Connect wiring to board (plus model).
8a
Review wiring connections.
DPS: 0.25A, 30VDC, Resistive
Contacts shown
in open-door state
MBS: 1A, 30VDC, Resistive
Contacts shown
in de-energized state
DC Power
8b
Connect wires to board.
From Door Frame
Multi Wire Cable
From LED
From MBS (2)
From MBS (1)
From Magnet
8d
Install Cover

Customer Service

1-877-671-7011
www.allegion.com/us
Printed Circuit Board
NO
TB3
NC
C
NO
NC
TB2
C
DC (+)
TB1
DC (-)
Polarized
From LED
Black/Red
Note: Two MBS
From MBS
plugs are
From MBS
interchangeable
RTD Adjuster
Min.
Max.
Time
Time
From Magnet
8c
Connect ATS wires.
ATS
NC (violet)
NO (gray)
C (white)
Switch Rating:
1A @ 30VDC, Resistive
44487296 Rev. 01/14-e