Sharp CV-10NH Installation And Operation Manual page 13

Portable room air conditioners
Table of Contents

Advertisement

Available languages

Available languages

If the inner width of the window is
between 24" (609mm) and 36.8"
(934mm) inclusive.
(1) Open the window sash and place the
window panel on the window stool.
(2) Slide the adjustment panel to fi t the
window frame width.
(3) Secure the window panel to the stool
with 3 screws.
If the inner width of the window is be-
tween 36.8" (934mm) and 48" (1219mm)
inclusive.
(1) Attach the extension panel to the
adjustment panel.
(2) Open the window sash and place the
window panel on the window stool.
(3) Slide the adjustment and extension
panels to fi t the window frame width.
(4) Secure the window panel to the window
stool with 4 screws.
5
Cut the foam seals (adhesive type) A
and B to the proper length and attach it
to the window panel.
Attach foam seal A to the window panel and
extension panel, and attach foam seal B to
the adjustment panel.
6
Close the window sash securely against
the Window panel.
7
Cut the foam seal to an appropriate
length and seal the opening between the
top of the inner window sash and the
outer window sash.
8
Attach the bracket with a screw.
24"~36.8"
Extension panel
36.8"~48"
Foam seal B
(adhesive type)
Foam seal
E-11
Adjustment panel
Foam seal A
(adhesive type)
Bracket

Hide quick links: