A.O. Smith RPV series Installation Instructions And Use & Care Manual page 9

Electric tankless water heater

Advertisement

Model
Recommended
Breaker Size
(Amps)
*P**-40-Y5
20
*P**-60-Y5
25
*P**-73-Y5
30
*P**-90-Y5
40
*
All wiring/conductors must be rated for 90°C or greater.
Maximum recommended wire size is #6 cu AWG.
This model may used with a 208 VAC supply. Use of 208 VAC may require different breaker and/or wire sizes.
Follow all code requirements.
Model
Recommended
Breaker Size
(Amps)
*2**-140-X5
40 amps each
(2 circuits)
*2**-120-E5
60 amps
*2**-140-E5
60 amps
*2**-160-E5
40 amps each
(2 circuits)
*2**-180-E5
40 amps each
(2 circuits)
Point-of-Use Models
(For potable water heating only. Not for space heating.)
NOTICE: Models sorted by Voltage, then by Wattage per Element.
Voltage
Number
of
Elements
277
1
277
1
277
1
277
1
Two-Chamber Models
(For potable water heating only. Not for space heating.)
NOTICE: Models sorted by Voltage, then by Wattage per Element.
Voltage
Number of
Elements
208
2
240
2
240
2
240
2
240
2
*
All wiring/conductors must be rated for 90°C or greater.
† Maximum recommended wire size is #6 cu AWG.
Wattage
Current per
per Element
Breaker
(KW)
(Amps)
4
14.44
6
21.66
7.3
26.35
9
32.49
Wattage per
Current per
Element (KW)
Breaker
(Amps)
7
33.65
6.1
50
7
58.34
8
33.33
9
37.5
Electric Tankless Water Heater
Recommended
Element Type
*
Wire Size
(AWG)
12
Single
10
Single
10
Single
8
Single
Recommended
Element
Type
*
Wire Size
(AWG)
8
Single
6
Single
6
Single
8
Single
8
Single
9