Model
Recommended
Breaker Size
(Amps)
*4**-280-X5
70 amps each
(2 cirucits)
*4**-180-E5
40 amps each
(2 circuits)
*4**-220-E5
50 amps each
(2 circuits)
*4**-240-E5
60 amps each
(2 circuits)
*4**-280-E5
60 amps each
(2 circuits)
*4**-320-E5
70 amps each
(2 circuits)
10
Electric Tankless Water Heater
Four-Chamber Models (Single Phase)
For potable water heating only. Not for space heating.
NOTICE: Models sorted by Voltage, then by Wattage per Element.
Voltage
Number of
Elements
208
4
240
4
240
4
240
4
240
4
240
4
*
† Maximum recommended wire size is #6 cu AWG.
Wattage per
Current per
Element (KW)
Breaker
(Amps)
7
67.31
4.5
37.50
5.5
45.83
6
50.00
7
58.33
8
66.67
All wiring/conductors must be rated for 90°C or greater.
Recommended
Element
Type
*
Wire Size
(AWG)
Single
6
8
Single
6
Single
Single
6
Single
6
Single
6