4. Insert all connection cables through the opening of the PRO device. Make sure that the
connection cables are not damaged.
5. Attach the device with 4 M4x12 screws to the base adapter from the top, torque 2.5 Nm.
Make sure that the connection cables are not crushed.
6. Connect all cables according to the description in the section below.
7. Fasten the backplane cover to the device with the 8 screws, torque 1.5 Nm. Check that
the seal is sitting correctly.
3.3.3

PRO devices for support arm (extendable, round tube)

Requirement
● One of the following support arm systems:
– Support arm with round tube end with outside diameter 48.3 mm, appropriate for the
– Support arm with mechanical interface, appropriate for the flange of the flange mount,
– Support arm with mechanical VESA interface, the corresponding Siemens adapter set
See also section "System components for PRO devices (Page 23)".
● The PRO device, all packaging components and protective films have been removed
● The lower cover of the PRO device from the accessory kit
● The following cables are fed through the support arm to which the device is mounted:
– Equipotential bonding cable
– Power supply cable
– Data cables, e.g. USB, DVI and DisplayPort connecting cable
Procedure
The following figures show an example of how to attach the PRO device to a support arm
system using the optionally available Siemens flange mount. The same approach is used to
mount the PRO device to a 48.3 mm round tube.
IFP, IFP PRO, IFP ETH
Operating Instructions, 11/2017, A5E31298376-AH
opening of the PRO device
When selecting the round tube, ensure that its inside diameter is large enough so that
all needed cables and their connectors can fit through.
and Siemens flange mount (not included in product package)
and the Siemens flange mount (not included in product package)
Recommendation: Route large connectors, such as DVI connectors, and their cables
through the support arm first.