Restoring the factory settings for an Ethernet Monitor

When the Ethernet Monitor was operated in the LAN network, it has an individual IP address.
When you connect the Ethernet Monitor to another location in the network, it is no longer
found because the Ethernet Monitor software is looking for the default IP address. When the
factory settings are restored, the IP address of the Ethernet Monitor is reset to the default
value "192.168.1.2".
You use the Reset button to restore the factory settings for the Ethernet Monitor.
Procedure
1. Switch off the device's power supply.
2. Press the reset button with a suitable tool and keep the reset button pressed.
3. Switch on the device's power supply and keep the reset button pressed for an additional
10 seconds.
During this the two LAN LEDs are deactivated briefly.