Create the virtual Fibre Channel interface (Port Channel) on both switches:
N5548-Bottom(config)#
N5548-Bottom(config)#
N5548-Bottom(config-if)#
N5548-Bottom(config-if)#
N5548-Bottom(config-if)#
N5548-Bottom(config-if)#
N5548-Top(config)#
N5548-Top(config)#
N5548-Top(config-if)#
N5548-Top(config-if)#
N5548-Top(config-if)#
N5548-Top(config-if)#
4. Create the FCoE VSAN and map it to the VLAN on the switches:
N5548-Bottom(config)#
N5548-Bottom(config-vlan)#
N5548-Bottom(config-vlan)#
N5548-Top(config)#
N5548-Top(config-vlan)#
N5548-Top(config-vlan)#
5. Configure the VLANs allowed to transverse the vPC links:
N5548-Bottom(config)#
N5548-Bottom(config-if)#
N5548-Bottom(config-vsan-db)#
N5548-Top(config)#
N5548-Top(config-vsan-db)#
N5548-Top(config-vsan-db)#
6. Bind the entry in the VSAN database on the switches:
N5548-Bottom(config)#
N5548-Bottom(config)#
N5548-Bottom(config-vsan-db)#
N5548-Bottom(config-vsan-db)#
N5548-Bottom(config-vsan-db)#
© 2014 Cisco | IBM. All rights reserved.
interface vfc 1032
switchport mode F
bind interface port-channel 201
no shut
interface vfc 1032
switchport mode F
bind interface port-channel 201
no shut
vlan 200
fcoe vsan 200
vlan 201
fcoe vsan 201
interface port-channel 20
switchport trunk allowed vlan 1, 200
interface port-channel 20
switchport trunk allowed vlan 1, 201
vsan database
vsan 200
vsan 200 interface vfc1032