PVI 36TL Installation and Operation Manual (Rev H)

4.4.4 System Configuration

Move the cursor to "4 Setting" in the main interface. Press ENT to enter the
password: UP -> DOWN -> UP -> DOWN. Press ENT to confirm, and set the current
system parameters, as shown in Figure 5-12. There are 7 submenus in "4 Setting": "1
ON/OFF", "2 Language", "3 Buzzer", "4 SysTime", "5 Commun.", "6 OtherCmd" and "7
NetConfig".
1 ON/OFF
2 Language
4 Setting
3 Buzzer
→4 SysTime
5 Commun
6 OtherCmd
7 NetConfig
(1) The inverter can be started and shut down with "1 ON/OFF" menu. Move the
cursor to "ON" and press ENT, "ON State" will then be indicated at the bottom of LCD;
move the cursor to "OFF" and press ENT, then "OFF State" will be indicated as well.