Technical Data

short description
transducer type
directional characteristics
frequency range
sensitivity
output impedance
maximum SPL
maximum output voltage
equivalent SPL due to inherent noise 20 dB SPL (CCIR-weighted)
output voltage due to inherent noise 8 V (CCIR-weighted)
S/N ratio at 94 dB SPL ( 1 Pa)
dynamic range
switchable pre-attenuation
switchable bass rolI-off
switchable treble emphasis
feeding
supply voltage / supply current
connector
diameter
length
weight
Subject to alterations.
20
high-frequency studio condenser
microphone with 5 switchable
directional characteristics
double push-pull pressure-gradient
transducer
omnidirectional, wide-angle cardioid,
cardioid, super cardioid, figure-8
30 - 50000 Hz
40 mV/Pa
ldB (-28 dB re 1 V/Pa)
150
136 dB SPL
(142 dB SPL with 6/12 dB preattenuation)
5 V
10 dB SPL (A-weighted)
2.5 V (A-weighted)
74 dB (CCIR-weighted)
84 dB (A-weighted)
116 dB (CCIR-weighted)
126 dB (A-weighted)
6/12 dB (20/10 mV/Pa)
3/6 dB at 50 Hz
3/6 dB at 8 kHz
phantom feeding P48
48
4 V / 3 mA
XLR-3
26.5 mm
178 mm
135 g